Maintenance of the vibration motor

|2015-02-11 09:03|3576 view

Each end of the shaft vibration motor has a fixed eccentric block and an adjustable eccentric block,adjustable between the eccentric block and a fixed eccentric block angle can change the size of theexciting force. The factory can be adjusted between the eccentric block and a fixed eccentric blockangle of 0 degrees, the exciting force when the rated exciting force of the vibrating motor of F, the exciting force at different angles:

Special attention should be paid to the adjustment, the exciting force, vibration motor shaft to both ends of the adjustable eccentric block to one side as the same angle adjustment.

The step of adjusting the excitation force

The removal of the protective cover.

Unscrew the fastening bolts, the outer side of the eccentric block.

Both sides should learn the eccentric block to rotate in the same direction, so that the shaft reticlealignment eccentric block vibration force showing the value of exciting force line to the required value, and check whether the ends for the same angle.

Excitation regulation

Vibration motor factory vibrating force to 80%, to sea (export) excitation force to 0%. Use the following steps to adjust:

Vertical vibration motor

The exciting force adjustment: remove the additional block compressing bolts, by increasing or decreasing the number of additional block to adjust the excitation force;

Secondly, the eccentric block, angle adjustment: on the eccentric block is fixed block, under theeccentric block is adjustable block, using the fastening bolts are pressed on the rotating shaft of the motor. Two end of the shaft is carved with reference line, an eccentric block are arranged on the outer surface of the rotating angle of the rotary ruler marked, Panasonic eccentric block pressing bolts, rotate the eccentric block, the lower eccentric block on the angle scale reticle alignment axisreference reticle, adjusted to the required angle, tighten the lower eccentric block pressure bolt; to regulate the eccentric angle, can be adjusted according to the corresponding method.

Horizontal vibration motor

The protective cover, loosen fastening screws, remove the two ends of the protective cover;

Secondly, the excitation force is less than MV50-2;

The exciting force greater than or equal to MV50-2, MV50-4, MV50-6, vibration motor MV30-8(containing the four specifications), the external eccentric block is fixed block, with the key is fixed on the rotating shaft, and can not rotate. The inner eccentric block is adjustable block, outer surface is provided with a marked maximum vibration force percentage ruler, pressing the fastening bolt used on a rotating shaft of the motor. Unscrew both inner sides of the inner eccentric blockpressing bolt, an eccentric block to rotate in the same direction, so that the exciting force in theeccentric block on the scale reticle alignment slotted external eccentric block, adjusted to the required excitation force, tighten the inner eccentric block pressing bolts, mount the protective cover;

Note: in addition to the special application, the two ends of the rotating shaft vibration motoreccentric block position must be correspondingly, at both ends of the eccentric block percentageset must be equal, otherwise the vibration motor will have a great wrong to the exciting force,vibration of mechanical damage to the motor.